Toho-electronics TTM-00BT Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 35
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
12
Voltage input parameters
a) Identifier b) Name c) R/W d) Description and set range e) Remark
Initial value (communication
numerical data)
TC, thermocouple;
Pt, resistance bulb
DIF
00000
Set a voltage input function
R/W
R/W of the voltage input function setting
Numerical
data
Function type
When voltage is
applied
00000 None
00001 SV/SV2 function SV2
00002 RUN/READY function READY
00003 Auto/manual function Manual
00004 Forward/reverse operation
function
Forward
operation
00005 Auto-tuning function AT start
00006 Forward operation
(SV2)/reverse operation
(SV) function
Forward
operation (SV2)
SV2
00000
Setting 2 R/W
r/w
R/W of the control setting 2
Set range: SLL to SLH
Unit common parameters
a) Identifier b) Name c) R/W d) Description and set range e) Remark
Initial value (communication
numerical data)
TC, thermocouple;
Pt, resistance bulb
AWT
00000
Response delay setting R/W R/W of the response delay setting
Set range: 0 to 250mS
Channel not specified
MBK
00001
Memory bank reading R/W Replaces the specified memory bank with the current
memory bank.
00001 to 00008 (example: memory bank 1 is 00001)
No writing is possible
during AT.
Vista de pagina 11