5.8 Common parameter setting mode SET 10
SET10
Name
Setting content
Initial value
1
INP1
Input type setting (*2) (*3)
0
K thermocouple
11
PR40-20
0
1
J thermocouple
12
PLII
2
T thermocouple
13
Pt100
3
E thermocouple
14
JPt100
4
R thermocouple
15
0 - 10 mV DC
5
S thermocouple
16
0 - 1 V DC
6
B thermocouple
17
0 - 5 V DC
7
N thermocouple
18
1 - 5 V DC
8
U thermocouple
19
0 - 10 V DC
9
L thermocouple
20
4 - 20 mA DC
10
WRe5-26
2
FSH1
Scaling upper limit setting (*2) (*3)
Current/voltage input only
FSL1 to 29999 (digit)
10000
3
FSL1
Scaling lower limit setting (*2) (*3)
Current/voltage input only
-19999 to FSH1 (digit)
-10000
4
PVG1
PV compensation gain setting
0.500 to 2.000 (times)
1.000
5
PVS1
PV compensation zero setting
Thermocouple/RTD input
-999.9 to 999.9 (C)
-999 to 999 (C)
0
Current/voltage input
-9999 to 9999 (digit)
6
PDF1
PV filter setting
0.0 to 99.9 (seconds)
0.0
7
PDFS
Special PV filter setting
0.0 to 99.9 (seconds)
0.0
8
DP1
Decimal point position
setting (*2) (*3)
Thermocouple/RTD input
0
0
Unit of 1C
0.0
Unit of 0.1C
Current/voltage input
0
1/digit
0.0
0.1/digit
0.00
0.01/digit
0.000
0.001/digit
0.0000
0.0001/digit
5.9 Common parameter setting mode SET 11
SET11
Name
Setting content
Initial value
1
BKUP
Backup of a setting value (*2) (*3)
Backup begins by holding the and keys pressed for 2 seconds.
During the backup, SAVE is displayed; turn-off of the display indicates
ended backup.
2
RESET
Initialization of a setting value (*2)
Initialization of the backup setting begins by holding both and keys
pressed for 2 seconds.
During initialization, LoAd is displayed and turn-off of the display
indicates ended initialization.