48-7009-E 6-79
■Repeat Start Step Setting / Repeat End Step Setting / Setting the Times of Execution / Setting the no. of
Execusion / No. of Times Monitor
Repeat Start Step Setting 3
Setting Value Range 1~Repeat End Step Setting
(ENdSt)
Repeat End Step Setting 3
Repeat Start Step Setting (StRSt StRSt)~
Setting No. of Steps to be used or StEPN
※When set to StEPN, the value which is set under the
Setting No. of Steps to be Used will be “Repeat End Step
Setting”.
No. of Execution Setting / No. of Execution Monitor 3
Setting Value Range RUNP=0~9999
(When RUNP=0, Infinite)
Setting the condition of repeated operation during the programmed operation
*5 Repeated Start Step Setting (StRSt)
This is to set the starting point of the repetition (Step No. of which the repetition starts)
*6 Repeated End Step Setting (ENdSt)
This is to set the end point of the repetition (Step No. of which the repetition ends)
*7 Setting No. of Executions / No. of Executions Monitor (RUNP)
This is to set the no. of time of repetition at the start point and end point.
NOTE: The setting value of the “No. of Executions Setting ” and “No. of Executions” done will be shown alternately only
on the display of the controller unit.
■Repeat Operation Behavior Diagram
STEP1 STEP2 STEP3 STEP2 STEP3 STEP2 STEP3 STEP4
programmed
operation
start
Repeated Start Step Setting : STEP2
Repeated End Step Setting : STEP3
Setting No. of Executions : 3 times
programmed
operation
end
Above is usage example of Repeat Operation Function