Toho-electronics TTM200 Manual de usuario Pagina 239

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 238
48-7009-E 7-8
(5) Power consumption 100 - 240 VAC: 10 VA or less (TTM-204)
100 - 240 VAC: 11 VA or less (other than TTM-204)
24 VAC/DC: 4 W or less (TTM-204)
(6) Warm-up time 30 minutes
(7) Momentary power outage No effect of power outage in a single cycle.
(Reset at power outage for more than a cycle)
For DC power with the outage for 40 ms or shorter, there is no effect on
operation.
(8) Isolation resistance Measurement terminal - case 00 VDC, 20 M
Power terminal - case 500 VDC, 20 M
(9) Withstand voltage Measurement terminal - case 1000 VAC for a minute
Power terminal - case 1500 VAC for a minute
(10) Weight TTM-204: 120 g or less
TTM-205: 210 g or less
TTM-207: 260 g or less
TTM-209: 300 g or less
(11) Protection structure IP66 or equivalent (on the front surface): Only for TTM-204
For TTM-205, 207 and 209, no IP regulation applicable.
(Due to installation for loader communication)
Vista de pagina 238
1 2 ... 234 235 236 237 238 239 240 241 242 243 244 ... 263 264

Comentarios a estos manuales

Sin comentarios