Toho-electronics TTM200 Manual de usuario Pagina 263

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 264
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 262
48-7009-E 7-32
7.5.16 Program setting mode (SET 22)
Setting data
Character
Setting (monitor) value
Initial value
Unit
Setting
value
Blind
Number-of-use-step
setting
StEPN
Setting value range
n = 1 to 8
8
None
Step designation
bank setting
St*bK
Setting value range
St*BK = 0 to 7
* 1 to (StEPN setting value)
0
None
Step SV setting
SV*
Setting value range
SV* = SLL to SLH
* 1 to (StEPN setting value)
* If SLL and SLH are set in a
bank, the values of SLL and SLH
are set for each bank.
0
C
Digit
Step time setting
tIM*
Setting value range
TIM* = 00:00 to 99:59
* 1 to (StEPN setting value)
0.00
Hour,
minute and
second
Repetitive start step
setting
StRSt
Setting value range
1 to repetitive end step setting
(ENdSt)
1
None
Repetitive end step
setting
ENdSt
Setting value range
Repetitive start step setting (StRSt
StRSt) to the number-of-use-step
setting or StEPN
* If a setting is made with StEPN,
the value set in the
number-of-use-step setting
becomes repetitive end step
setting.
StEPN
None
Repetitive count
setting
RUNP
Setting value range
RUNP = 0 to 9999
RUNP 0: Unlimited count
1
Times
Note SET 22 is selectable only on Ver3.xx or later.
Vista de pagina 262
1 2 ... 258 259 260 261 262 263 264

Comentarios a estos manuales

Sin comentarios